Sale!

Large Size Data centre Enterprise Environment Monitoring System E-16D

Original price was: KSh 310,669.00.Current price is: KSh 248,535.00.

Descriptions

The ENVIROMUX Enterprise Environment Monitoring System monitors critical environmental conditions, such as temperature, humidity, liquid water presence, power, intrusion, and smoke. When a sensor goes out of range of a configurable threshold, the system will notify you via email, LEDs, alarm beacon, siren, web page, network management (SNMP), voice phone calls (via Automatic Voice Dialer System), and SMS messages (via external USB 3G modem).

The system includes three internal sensors: temperature, humidity and power. It also supports 16 external configurable sensors, eight digital input sensors, and four output relays for control of external devices.

  • Monitor and manage server room environmental and security conditions over IP.
  • Sensors supported:
    • 16 external configurable sensors
    • 8 digital inputs sensitive to contact closure
    • 8 Remote Temperature/Humidity Sensors over IP
    • Internal sensors – temperature, humidity, power
  • Four output relays for control of external devices.
  • Supports IP network video cameras for live view of any facility.
  • Monitor (ping) up to 64 IP network devices.
  • Create multiple alerts for any installed sensor.
  • Sensor conditions (events) can be configured to trigger alerts by themselves, and/or be used in combination with other events to trigger Smart Alerts.
  • Alerts are posted in message log, which is accessible through Web user interface.
  • Automatically configures network settings received from a connected DHCP server.
  • Integrates with various Open Source monitoring packages – Nagios and MRTG.
  • USB ports for connecting USB modem or for downloading log data to USB flash drive.
  • Internal battery backup.
  • Up to five units can be connected via Ethernet connection or using CAT5 expansion cables to increase the number of sensors connected.
  • 1RU rack mount case is standard.
  • Security: HTTPS, SSHv2, SSLv3, IP Filtering, LDAPv3, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
  • Use in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, or any unmanned area that needs to be monitored.
SKU: E-16D Category:

Specs

 

Enterprise Server Environment Monitoring System Specifications Drawing
1. Power Port
  • Input: 100 to 240 VAC at 50 or 60 Hz via IEC connector. (Country-specific power supply cable included.)
  • Power consumption: 35W
  • Connection for Earth Ground.
  • Fuse protection.
  • Optional 48VDC power (not shown).
    • Accepts 36~72VDC (48VDC nominal).
  • Optional 24VDC power (not shown).
    • Accepts 20~32VDC (24VDC nominal).
  • Optional dual power (not shown).
    • Available on AC, 48VDC, and 24VDC models.
    • If the first power source fails, the unit will automatically, without interruption, switch over to the second power source before switching to the battery backup.
2. RJ45 Sensor Ports
  • Sixteen RJ45 modular jacks for connecting NTI temperature, humidity, temperature/humidity, liquid detection, smoke detection, glass break, vibration and motion sensors.
3. Digital Inputs
  • Eight screw terminals pairs for connecting dry contact devices.
  • Input voltage: 0VDC to +25VDC.
  • Provides +12VDC, 50mA for terminals 1-7, and +12VDC, 350mA for terminal 8 only.
  • Fuse protection.
4. Digital Outputs
  • Four screw terminals pairs.
  • Potential-free relay switch contacts.
  • Normally open / normally closed connection points.
  • Maximum switching load: 0.5A at 100VAC, 1A at 30VDC, 0.5A at 48VDC.
5. Beacon Port
  • One screw terminal pair.
  • Provides +12VDC, 180 mA to supply an alarm beacon.
  • Fuse protection
6. Siren Port
  • One screw terminal pair.
  • Provides +12VDC, 180 mA to supply a siren.
  • Fuse protection
7. AUX Power
  • One screw terminal pair.
  • Provides 12VDC, 150mA.
8. USB Device Ports
  • Four female USB Type A connectors for connecting USB modem or for downloading log data to USB flash drive.
    • Two USB ports on front panel and 2 on back panel.
9. USB Console Port
  • One female USB Type B connector for connecting a PC for serial terminal access.
10. RS232 (DCS) Port
  • One female RJ45 serial port for terminal access.
11. Ethernet Port
  • One 10/100 Base-T Ethernet port with RJ45 Ethernet connector.
    • Supports full- and half-duplex.
12. RS232 AUX Port
  • One RJ45 port for connecting a serial GSM modem or a remote serially-controlled device.
13. Cascade In/Out Ports
  • Two RJ45 jacks.
  • A maximum of 5 systems can be used in a cascaded configuration via RS485 to increase the number of sensor ports (1 master, 4 slaves).
    • Each slave unit needs its own unique RS485 address value that can range from 1-255.
    • Use CAT5/5e/6 patch cables with RJ45 connectors wired straight through
    • Up to 4,000 feet between the master unit and the slave unit.
    • The last slave must have a terminating plug (E-TRMPLG, not included) in the empty socket.
  • Uses a single Web interface for all systems connected.
Protocols
  • HTTP/HTTPS, SNMP V1/V2c/V3, SMTP, TCP/IP, Syslog, SNTP, DHCP, SSHv2, SSLv3, TLS v1.2, LDAPv3, XOAUTH2, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour, IPV6, WAP 2.0, RADIUS
    • Support for XOAUTH2 provides higher security authentication for email accounts (e.g. Gmail).
  • Compatible with any SNMP management software.
    • The unit can be polled via SNMP.
  • Operates and configures via HTTP/HTTPS web page, Telnet, SSH, or USB/RJ45 serial interface.
    • Supports Internet Explorer 6.0 and higher, Firefox 1.5 and higher, Netscape 9, Google Chrome, Safari 1.3 and higher for MAC, and Safari 3.0 and higher for PC.
    • Multiplatform support: Windows 7/8/10, Windows Server 2008/2012/2016/2019, Solaris, Linux, FreeBSD, and MAC OS 10/11.
  • An IP address can be assigned to the E-16D automatically by a DHCP server.
  • Generates SNMP traps, email alerts, syslog messages, and SMS messages (via USB 3G modem).
    • Alerts are posted in event log, which is accessible through Web user interface.
    • Email alerts can be sent to 17 addresses.
      • Users can configure the schedule for when they will be alerted, as well as customize the e-mail subject line for each sensor alert.
    • SNMP traps have unique OID’s (Object Identifiers) for each sensor.
  • Supports HTTP REST API to poll sensor data with response in JSON format.
Internal Temperature Sensor
  • For monitoring the temperature inside the E-16D case.
    • Use an external temperature sensor for monitoring ambient air temperature.
  • Applications from 32 to 104°F (0 to 40°C).
  • Temperature accuracy:
    • ±1.44°F (±0.8°C) for 32 to 41°F (0 to 5°C).
    • ±0.72°F (±0.4°C) for 41 to 104°F (5 to 40°C).
Internal Humidity Sensor
  • For monitoring the humidity inside the E-16D case.
    • Use an external humidity sensor for monitoring humidity in the air.
  • Applications from 20% to 80% relative humidity at temperatures between 32 to 104°F (0 to 40°C).
  • Accurate to within ±3% relative humidity (at 77°F/25°C).
Internal Power Sensor
  • Measures mains voltage: 0 to 255 VAC
  • Measures battery voltage: 0 to 20 VDC
  • Measures voltage on 24VDC models: 20 to 32VDC
  • Measures voltage on 48VDC models: 36 to 72VDC
  • Alerts are sent when there is a power outage and when power returns.
Back-up Battery
MTBF
NTI Part # Hours
E-16D 89,884
E-16DDP 107,046
E-16D-24V 115,143
E-16D-24VDP 121,484
E-16D-48V 115,143
E-16D-48VDP 121,484
E-16DEL 89,884
Dimensions
  • WxDxH (all options):
    • Without supplied rackmount kit: 16.19×10.01×1.75″
    • With supplied rackmount kit: 19×10.01×1.75″
Weight
  • E-16D: 9.5 lb (4.31 kg).
  • E-16D-48VDP: 9.6 lbs (4.36 kg).
Environmental
  • Operating temperature: 32 to 104°F (0 to 40°C).
  • Storage temperature: -22 to 140°F (-30 to 60°C).
  • Operating/Storage Relative Humidity: 5 to 90% non-condensing RH.
Regulatory Approvals
  • CE, RoHS
  • TAA compliant
Warranty
  • Two years
Shopping Cart