Sale!

Remote Temperature/Humidity Sensor over IP, POE E-MICRO-TRHP

Original price was: KSh 82,688.00.Current price is: KSh 66,150.00.

E-MICRO-TRHP: Micro environment monitoring system

with integrated temperature/humidity sensor and PoE 


• Integrated temperature/humidity combination sensor
• 2x RJ45 ports for external temperature/humidity sensors
• 2x digital inputs sensitive to contact closure
• Built-in power over Ethernet (PoE)
• Dual DC power provides triple redundancy
• No power supply included

ENVIROMUX® environment monitoring systems.

ENVIROMUX® Micro environment monitoring system (EMS) monitors and manages server room environmental and security conditions over IP, providing early warnings before critical events turn into disaster.

ENVIROMUX® Micro monitors critical environmental conditions, such as temperature, humidity, liquid water presence, power, intrusion, and smoke. When a sensor goes out of range of a configurable threshold, the system will notify you via email, web page, network management (SNMP), and/or SMS messages (via email-to-SMS).

The system functions independently or as an IP-connected remote sensor for the E-2D/5D/16D.

E-MICRO-T features an integrated temperature sensor, two RJ45 sensor ports for external temperature/humidity sensors, and two dry contact inputs.

EnviromuxSensors Supported
• 2 temperature/humidity sensors
• 2 digital inputs sensitive to contact closure

Features and Benefits
• 1x integrated temperature/humidity combination sensor
• 2x RJ45 ports for external temperature/humidity sensors
• 2x digital inputs sensitive to contact closure
• Dual DC power provides triple redundancy
• Sensors are hot plugable
• Monitor (ping) up to 4 IP network devices – alerts are sent if devices are not responding
• Create multiple alerts for any installed sensor
• Sensor conditions can be configured to trigger alerts by themselves, and/or be used in combination with other alerts to trigger one Smart Alert
• Configure up to 32 alerts, and one Smart Alert
• Alerts are posted in message log, which is accessible through Web user interface
• Supports 4 IP network video cameras for live view of any facility
• Integrates with various open source SNMP monitoring packages – Nagios
• The unit can be polled via SNMP

Use in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, or any unmanned area that needs to be monitored.

Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 ENVIROMUX units and all connected sensors.

Security
• HTTPS
• TLS v1.2
• AES 256-bit encryption
• IP Filtering
• 16-character username/password authentication
• User account restricted access rights

Web Interface
• Configuration can be done over the Internet/LAN via Web page.
• When connected as an IP remote sensor for an E-2D/5D/16D unit, the E-MICRO is configured via the E-xD web interface.
• Supports Internet Explorer 6.0 and higher, Firefox 1.5 and higher, Netscape 9, Google Chrome, Safari 1.3 and higher for MAC, and Safari 3.0 and higher for PC.
• Configure sensor thresholds, alarm methods, formats of alerts, and system data log.
• View/edit sensors’ current values, thresholds and alert statuses.
• All sensors connected to the E-MICRO can be viewed on one summary page.
• User configurable settings allow sensors to return to normal status when alert condition clears, without manually acknowledging/dismissing the alert.
• View/edit entries stored in the system logs.
• Event log records system alerts.
• Stores up to 200 entries.
• Data log records samples of sensor readings per minute.
• Stores up to 43,000 entries per sensor.
• The data log can be downloaded as a comma-separated plain text file.
• Configure IP information (address, subnet mask, default gateway, DNS, etc.), user administrative settings, and data logging settings.
• Up to 9 users can access the web page at one time.
• Permissions, schedule and alert methods are configurable for each user.
• Configure up to 32 sensor conditions (alerts).
• Configure 1 Smart Alert to use different alert combinations to send alert messages.

Telnet
• Monitor over the text-based menu system accessible via Telnet.
• Access is controlled via username/password.
• System stores encrypted login information.
• Two user levels: user and administrator.
• Telnet can be enabled or disabled.
• Network Security Enhancement: Disabling Telnet can prevent unsecure text menu access to the E-MICRO.

Network Operation
• SNMP support, allowing integration into network management platforms.
• Updating the system firmware.

Optional Management Software
• Optional intuitive graphical management software provides an easy-to-use, unified interface for both monitoring and configuring up to 3,000 ENVIROMUX units and all connected sensors.
• Push configuration changes to multiple connected units in a group at once e.g. new users, mail server, network settings, security settings, system settings, etc.
• Choose between Enterprise Management Software or Low-Cost Management Software.
• E-MNG Enterprise Management Software – use to monitor and configure up to 3,000 E-2D/5D/16D, E-MICRO-T(RHP), E-1W(P), E-SEMS-16(U), IPDU-S4/8 units and all connected sensors.
• E-MNG-LC Low-Cost Management Software – use to monitor and configure up to 3,000 E-MICRO-T(RHP) and E-1W(P) units and all connected sensors

Open Source Monitoring Integration
• SNMP Plugin for Nagios
• NTI SNMP Plugin for Zabbix
• Data Logging using Syslog

SKU: E-MICRO-TRHP Category:

Specifications

RJ45 Sensor Ports
• Two RJ45 modular jacks for connecting temperature sensors or combined temperature/humidity sensors.
• Three levels of user-defined alerts – normal, warning, critical.

Dry Contact Closures
• Two screw terminal pairs for connecting dry contact devices and the liquid detection sensor.

USB Port
• One female Micro USB connector – reserved for future use.

Ethernet Port
• One female RJ45 connector.
• 10/100 Base-T Ethernet interface.

Protocols
• HTTP/HTTPS, SNMP V1/V2c, SMTP, TCP/IP, Syslog, SNTP, DHCP, TLS v1.2, AES 256-bit, 3DES, Blowfish, RSA, EDH-RSA, Arcfour.
• Compatible with any SNMP management software.
• The unit can be polled via SNMP.
• Operates and configures via HTTP/HTTPS web page.
• An IP address can be assigned to the E-MICRO automatically by a DHCP server.
• Generates SNMP traps, email alerts, syslog messages, and SMS messages (via email-to-SMS).
• Alerts are posted in event log, which is accessible through Web user interface.
• Email alerts can be sent to 9 addresses.
• Users can configure the schedule for when they will be alerted.

Integrated Temperature Sensor
• Applications: from -4 to 167°F (-20 to 75°C).
• Accuracy (in moving air – minimum airflow 8.2 ft/s (2.5 m/s)): ±0.72°F at 14 to 167°F (±0.4°C at -10 to 75°C); ±0.9°F at -4 to 14°F (±0.5°C at -20 to -10°C).
• Resolution: 0.2°F (0.1°C).

Physical
• Dimensions (WxDxH): 4 x 3.44 x 1.37 in. (102 x 87 x 35 mm).
• Includes mounting holes to match rack hole spacing.

Power
• Built-in power over Ethernet (PoE) and dual DC power provides triple redundancy.
• Power over Ethernet standards supported: IEEE 802.3af, 802.3at.
• Proprietary schemes such as Cisco Discovery Protocol are not supported.
• Similar legacy switches and routers will have to use PWR-SPLY-ELC.
• If the first power source fails, the unit will automatically, without interruption, switch over to the second power source.
• The unit draws power from the source with the highest DC voltage (nominal 5.5V).
• If two or more sources have exactly the same voltage, it will draw in part from each of them.
• 110 to 240 VAC at 50 or 60 Hz via AC adapter (not included).
• Country-specific AC adapters sold separately (PWR-SPLY-ELC).
• Input voltage: 5.5VDC ±5%
• Power consumption: 4W max.

Environmental
• Operating and Storage Temperature: -4 to 167°F (-20 to 75°C).
• Operating and Storage Relative Humidity: 0 to 90% non-condensing RH.
• MTBF: 628,394 hours.
• Regulatory Approvals: CE, RoHS.

Shopping Cart
Scroll to Top